Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Science ; 383(6687): 1096-1103, 2024 Mar 08.
Article in English | MEDLINE | ID: mdl-38452063

ABSTRACT

Monitoring homeostasis is an essential aspect of obtaining pathophysiological insights for treating patients. Accurate, timely assessments of homeostatic dysregulation in deep tissues typically require expensive imaging techniques or invasive biopsies. We introduce a bioresorbable shape-adaptive materials structure that enables real-time monitoring of deep-tissue homeostasis using conventional ultrasound instruments. Collections of small bioresorbable metal disks distributed within thin, pH-responsive hydrogels, deployed by surgical implantation or syringe injection, allow ultrasound-based measurements of spatiotemporal changes in pH for early assessments of anastomotic leaks after gastrointestinal surgeries, and their bioresorption after a recovery period eliminates the need for surgical extraction. Demonstrations in small and large animal models illustrate capabilities in monitoring leakage from the small intestine, the stomach, and the pancreas.


Subject(s)
Absorbable Implants , Anastomotic Leak , Gastrointestinal Tract , Ultrasonics , Animals , Humans , Homeostasis , Stomach , Gastrointestinal Tract/surgery , Anastomotic Leak/diagnostic imaging , Models, Animal
2.
Biosens Bioelectron ; 237: 115545, 2023 Oct 01.
Article in English | MEDLINE | ID: mdl-37517336

ABSTRACT

Temperature is the most commonly collected vital sign in all of clinical medicine; it plays a critical role in care decisions related to topics ranging from infection to inflammation, sleep, and fertility. Most assessments of body temperature occur at isolated anatomical locations (e.g. axilla, rectum, temporal artery, or oral cavity). Even this relatively primitive mode for monitoring can be challenging with vulnerable patient populations due to physical encumbrances and artifacts associated with the sizes, weights, shapes and mechanical properties of the sensors and, for continuous monitoring, their hard-wired interfaces to data collection units. Here, we introduce a simple, miniaturized, lightweight sensor as a wireless alternative, designed to address demanding applications such as those related to the care of neonates in high ambient humidity environments with radiant heating found in incubators in intensive care units. Such devices can be deployed onto specific anatomical locations of premature infants for homeostatic assessments. The estimated core body temperature aligns, to within 0.05 °C, with clinical grade, wired sensors, consistent with regulatory medical device requirements. Time-synchronized, multi-device operation across multiple body locations supports continuous, full-body measurements of spatio-temporal variations in temperature and additional modes of determining tissue health status in the context of sepsis detection and various environmental exposures. In addition to thermal sensing, these same devices support measurements of a range of other essential vital signs derived from thermo-mechanical coupling to the skin, for applications ranging from neonatal and infant care to sleep medicine and even pulmonary medicine.

3.
Sci Adv ; 8(51): eade3201, 2022 12 23.
Article in English | MEDLINE | ID: mdl-36563148

ABSTRACT

Recently reported winged microelectronic systems offer passive flight mechanisms as a dispersal strategy for purposes in environmental monitoring, population surveillance, pathogen tracking, and other applications. Initial studies indicate potential for technologies of this type, but advances in structural and responsive materials and in aerodynamically optimized geometries are necessary to improve the functionality and expand the modes of operation. Here, we introduce environmentally degradable materials as the basis of 3D fliers that allow remote, colorimetric assessments of multiple environmental parameters-pH, heavy metal concentrations, and ultraviolet exposure, along with humidity levels and temperature. Experimental and theoretical investigations of the aerodynamics of these systems reveal design considerations that include not only the geometries of the structures but also their mass distributions across a range of bioinspired designs. Preliminary field studies that rely on drones for deployment and for remote colorimetric analysis by machine learning interpretation of digital images illustrate scenarios for practical use.

4.
Sci Adv ; 8(40): eabp9169, 2022 Oct 07.
Article in English | MEDLINE | ID: mdl-36197971

ABSTRACT

Local electrical stimulation of peripheral nerves can block the propagation of action potentials, as an attractive alternative to pharmacological agents for the treatment of acute pain. Traditional hardware for such purposes, however, involves interfaces that can damage nerve tissue and, when used for temporary pain relief, that impose costs and risks due to requirements for surgical extraction after a period of need. Here, we introduce a bioresorbable nerve stimulator that enables electrical nerve block and associated pain mitigation without these drawbacks. This platform combines a collection of bioresorbable materials in architectures that support stable blocking with minimal adverse mechanical, electrical, or biochemical effects. Optimized designs ensure that the device disappears harmlessly in the body after a desired period of use. Studies in live animal models illustrate capabilities for complete nerve block and other key features of the technology. In certain clinically relevant scenarios, such approaches may reduce or eliminate the need for use of highly addictive drugs such as opioids.

5.
Science ; 376(6596): 1006-1012, 2022 05 27.
Article in English | MEDLINE | ID: mdl-35617386

ABSTRACT

Temporary postoperative cardiac pacing requires devices with percutaneous leads and external wired power and control systems. This hardware introduces risks for infection, limitations on patient mobility, and requirements for surgical extraction procedures. Bioresorbable pacemakers mitigate some of these disadvantages, but they demand pairing with external, wired systems and secondary mechanisms for control. We present a transient closed-loop system that combines a time-synchronized, wireless network of skin-integrated devices with an advanced bioresorbable pacemaker to control cardiac rhythms, track cardiopulmonary status, provide multihaptic feedback, and enable transient operation with minimal patient burden. The result provides a range of autonomous, rate-adaptive cardiac pacing capabilities, as demonstrated in rat, canine, and human heart studies. This work establishes an engineering framework for closed-loop temporary electrotherapy using wirelessly linked, body-integrated bioelectronic devices.


Subject(s)
Absorbable Implants , Cardiac Pacing, Artificial , Pacemaker, Artificial , Postoperative Care , Wireless Technology , Animals , Dogs , Heart Rate , Humans , Postoperative Care/instrumentation , Rats
6.
J Vis Exp ; (176)2021 10 20.
Article in English | MEDLINE | ID: mdl-34747395

ABSTRACT

Peripheral nerve interfaces are frequently used in experimental neuroscience and regenerative medicine for a wide variety of applications. Such interfaces can be sensors, actuators, or both. Traditional methods of peripheral nerve interfacing must either tether to an external system or rely on battery power that limits the time frame for operation. With recent developments of wireless, battery-free, and fully implantable peripheral nerve interfaces, a new class of devices can offer capabilities that match or exceed those of their wired or battery-powered precursors. This paper describes methods to (i) surgically implant and (ii) wirelessly power and control this system in adult rats. The sciatic and phrenic nerve models were selected as examples to highlight the versatility of this approach. The paper shows how the peripheral nerve interface can evoke compound muscle action potentials (CMAPs), deliver a therapeutic electrical stimulation protocol, and incorporate a conduit for the repair of peripheral nerve injury. Such devices offer expanded treatment options for single-dose or repeated dose therapeutic stimulation and can be adapted to a variety of nerve locations.


Subject(s)
Electric Stimulation Therapy , Peripheral Nerves , Animals , Electric Power Supplies , Electric Stimulation Therapy/methods , Peripheral Nerves/physiology , Peripheral Nerves/surgery , Phrenic Nerve , Prostheses and Implants , Rats , Wireless Technology
7.
Materials (Basel) ; 13(13)2020 Jul 04.
Article in English | MEDLINE | ID: mdl-32635558

ABSTRACT

Recently, the use of oxide-based nanomaterials for bio-imaging has received great attention owing to their remarkable stabilities as compared to those of conventional organic dyes. Therefore, the development of scalable methods for highly luminescent oxide materials with fine control of size has become crucial. In this study, we suggested modified flame spray pyrolysis (FSP) as a scalable method to produce a green-light emitting phosphor-Tb-doped Y2O3-in the nanometer size range. In our FSP method, an alkali salt (NaNO3) was found to be highly effective as a size-controlling agent when it is simply mixed with other metal nitrate precursors. The FSP of the mixture solution resulted in oxide composites of Y2O3:Tb3+ and NaxO. However, the sodium by-product was easily removed by washing with water. This salt-assisted FSP produced nano-sized and well-dispersed Y2O3:Tb3+ nanoparticles; their crystallinity and luminescence were higher than those of the bulk product made without the addition of the alkali salt. The nanoparticle surface was further coated with silica for biocompatibility and functionalized with amino groups for the attachment of biological molecules.

8.
Nanotechnology ; 28(1): 015702, 2017 Jan 06.
Article in English | MEDLINE | ID: mdl-27897137

ABSTRACT

We studied temperature-dependent photoluminescence (PL) spectra of lead selenide (PbSe) dendrites and cubes grown by a solvothermal method. Their PL peaks were located at ∼8 µm at 10 K with a full width at half maximum (FWHM) of 10 meV. Using the temperature-dependent FWHM values, we obtained carrier-phonon coupling coefficients for PbSe. We also demonstrated mechanochemical synthesis of polycrystalline PbS nanoparticles and their successful conversion into a PbSe layer composed of nanocrystals by a selenization process with thermal treatment. The nanocrystals were found to be formed by the orientation alignment of small grains in the process. The PL peak energies of the PbSe layers as well as the PbSe dendrites and the cubes agreed well with their absorption edges in the transmission spectra, indicating that the photoluminescence originates from the band-edge emission. The band-edge emissions hold promise for the development of potential mid-infrared light sources using PbSe fabricated by these methods.

SELECTION OF CITATIONS
SEARCH DETAIL
...